Free delivery: Get free standard delivery on every order with Sky Store

Free delivery: Get free standard delivery on every order with Sky Store

Free delivery: Get free standard delivery on every order with Sky Store

RECIRCULATION LAMINAR AIR FLOW SYSTEM
RECIRCULATION LAMINAR AIR FLOW SYSTEM

RECIRCULATION LAMINAR AIR FLOW SYSTEM

Category: Clean Room Equipments

INR 80000

(Inclusive of All Taxes)

SKU : WEBER001SK36

MPN : WEBER001K36

Product ID : WEBER1K36

Brand : Weber

Availability : In Stock

Condition : New

Min Order Qty : 1

Shipping : Free Shipping

Delivery : 7-14 Business Days

Returns : Read Return Policy in Policy Centre (On Footer)

Country Of Origin : INDIA

WEIBER Recirculation Laminar Air Flow System uses internal air by means of recirculation. These systems are ideal solution for laboratory testing, low risk pharmaceutical compounding and more. They are most suitable for bacteriological, toxicology, where the presence of highly air borne particles, bacterial and viral need to be controlled to provide clean working conditions.

 Our unit has unique airflow system that ensures consistent airflow and HEPA filter loading, significantly improving filter life. It provides reasonable user protection with its strong air barrier containment thus, reducing pharmacists or operators fatigue which in turn increases user safety.

OPERATING PRINCIPLE :

Ceiling Recirculation Module:

Ceiling recirculation module are placed in the intermediate ceiling of the area. Recirculation models are equipped, with fluff separator, pre-filter, sound absorber, cool battery dry cooling (option), ventilator and a sound absorber. It extracts the air from the periphery and bring it back into the canopy above the HEPA filters. Depending on the total (recirculation) air volume the quantity of recirculation modules are selected.

Wall Recirculation Module:

Wall recirculation modules can be placed in front or integrated in the wall. Wall Recirculation modules are equipped, with steel plated grill, pre-filter, sound absorber, fan, end-sound absorber and cooling battery (option). The recirculation module extracts the air from the periphery and bring it back into the canopy above the HEPA filters. Depending on the total (recirculation) air volume the quantity of recirculation modules are selected.

 

SPECIAL FEATURES:

1. 2 options- ceiling and wall recirculation models available

2. Larger working area.

3. Easy to use

4. Accurate functioning

5. Microprocessor based controls

6. Sturdy Construction

7. Ensure minimum possible noise

8. HEPA filter for better efficiency

9. Microprocessor based controls

 

TECHNICAL MATRIX:

Cabinet construction

SS-304

Frequency

50 Hz

Nominal voltage

220-230 volts

Air flow

Unidirectional

Air flow rate

90±20fpm

Noise pressure(dB) (A)

<54dB

Pre filter unit

Washable pre filter unit

Illumination

Fluorescent light illumination greater than 800 lux

Power Requirements

500-750 watts

 

APPLICATIONS:

1. Bio-assays and sterility testing

2. Operation theatres

3. Microbiological manipulations

4. Animal husbandry

5. Biotechnology

6. microelectronics

WEIBER Recirculation Laminar Air Flow System uses internal air by means of recirculation. These systems are ideal solution for laboratory testing, low risk pharmaceutical compounding and more. They are most suitable for bacteriological, toxicology, where the presence of highly air borne particles, bacterial and viral need to be controlled to provide clean working conditions.

 Our unit has unique airflow system that ensures consistent airflow and HEPA filter loading, significantly improving filter life. It provides reasonable user protection with its strong air barrier containment thus, reducing pharmacists or operators fatigue which in turn increases user safety.

OPERATING PRINCIPLE:

Ceiling Recirculation Module:

Ceiling recirculation module are placed in the intermediate ceiling of the area. Recirculation models are equipped, with fluff separator, pre-filter, sound absorber, cool battery dry cooling (option), ventilator and a sound absorber. It extracts the air from the periphery and bring it back into the canopy above the HEPA filters. Depending on the total (recirculation) air volume the quantity of recirculation modules are selected.

Wall Recirculation Module:

Wall recirculation modules can be placed in front or integrated in the wall. Wall Recirculation modules are equipped, with steel plated grill, pre-filter, sound absorber, fan, end-sound absorber and cooling battery (option). The recirculation module extracts the air from the periphery and bring it back into the canopy above the HEPA filters. Depending on the total (recirculation) air volume the quantity of recirculation modules are selected.

- YOU MIGHT ALSO LIKE